UndergroundBackups
offers a wide range of storage services from our
data center located in the Springfield Underground
in Springfield Missouri. At approximately 85 feet
underground, our facility is not only state-of-the-art,
but one of a kind. If your seeking the ultimate
solution for data backup, disaster recovery, business
resumption planning, and/or industry compliance,
UndergroundBackups is IT! |
| |
| Security |
 |
|
Security
is based on a combination of posted security guards, security
cardkey access levels, visual inspection, video monitoring,
and biometrics. Individual data buildings have been constructed
to provide a building in a building concept.
This concept delineates the access security to a more
restrictive level. |
| |
| Electric |
 |
|
Four
electric substations are all located within 2 miles of
the site. A 161 kV transmission line crosses the development
adding additional reliability by tying in City Utilities
McCartney Generating Station. This facility offers a total
of 100 MW from (2) 50 Mw gas fired combustion turbines
all within 3 miles of the Springfield Underground. Specifically
within the data center, the utility power is N+1 backed-up
and conditioned by parallel redundant UPSs. Additionally,
a 2 MW generator stands by ready to provide back-up power
in the unlikely event of an interruption. All electric
transformation, switchgear, distribution, UPSs,
and back-up generation, including fuel are located underground
to ensure continuous operations during a natural/unnatural
event. |
| |
| Environmental |
 |
|
A
three pipe chilled water system serves the undergrounds
cooling requirements via redundant Liebert units to precisely
control the environment within each building. All system
chillers and ancillary equipment are located underground
to ensure continuos operations during a natural/unnatural
event. One of the many benefits of being underground is
that the natural air temperature is 60° - 64°F
year-round, which serves to naturally provide the ideal
computing atmosphere. Additionally, two dehumidification
units maintain 50% humidity within the common area to
enhance the mines natural environment. Fire suppression
within each building is provided by FM-200 fire protection
systems. The common area is protected by a double interlock
zoned sprinkler system to ensure loss prevention. Fire
detection is not only provided by standard smoke and ionization
detection systems, but also VESDA is utilized within areas
of the facility. |
| |
|
|
 |
 |
 |
|
"Having the counties
data backed up in a secure facility
85 feet underground gives me peace
of mind. I recommend this backup solution
to other government agencies or anybody
that has critical data."
|
Ted
Nichols
Christian County Collector |
| |
|
"Our database is
the lifeblood of our business, without
it we would be out of business. Underground
Backups gives me the assurance that
our data is secure from any disaster,
natural or otherwise. They give me
the peace of mind to sleep well at
night."
|
John
Foglesong
DD Hamilton |
| |
|
"With respect
to our data, Underground Backups
provides us with a disaster
preparedness plan. It is an
easy, hands-off backup process
that keeps us up-to-date with
the latest hardware, software
and updates. With data that
is irreplaceable, this was an
easy decision."
|
Jeff
Hudlin
ahpac.org |
| |
|
"Websites
and web hosting is our business.
Underground Backups takes care
of our servers backups. Knowing
that our clients data backups
are 85 feet underground safe
and secure makes us rest assured."
|
Mike
Torner
4goodhosting.com |
| |
| |
|
|
|
|